Module - Ultra Charts

Requirements & Compatibility

Requirements & Compatibility

Ignition Compatibility

Module Version

Ignition Version

Java Version Supported

1.0.x

8.1.30+ / 8.3.x

Java 11 / Java 17

0.9.x (Beta)

8.1.10 - 8.1.54

Java 11

System Requirements

  • Ignition: One Ignition gateway with the Perspective module installed.

    • Supported versions:

      • Ignition 8.1.30 or newer in the 8.1 line.

      • Ignition 8.3.x.

    • Supported configurations:

      • Standalone gateway running Perspective.

      • Redundant gateway pair running Perspective.

      • Development, test, and production gateways using the same compatible Ultra Charts build.

  • OS: Any 64-bit operating system supported by the target Ignition version.

  • Databases: None required by the module. Chart data must be provided by the Perspective project through properties, bindings, scripts, queries, or other project-owned data sources.

  • Other Required Modules: Ignition Perspective module and Ignition base gateway.

Ignition Edge support has not been validated for Ultra Charts. Use a full Ignition gateway for supported deployments.

Deployment Notes

  • Install the Ultra Charts module on every gateway where Perspective Designer or Perspective sessions need to use the chart components.

  • The module registers components in the Perspective Designer palette under the Ultra Charts category.

  • Chart configuration, bindings, and event handlers are stored in the Perspective project. The module does not maintain a separate chart database or external chart server.

  • For Ignition 8.3 upgrades, validate the project in a development or test gateway before production and verify that all required third-party modules are compatible with the target Ignition version.

Compatibility Notes

  • Ignition 8.1.33 and newer use Java 17; earlier supported 8.1 versions use Java 11. Use the Java runtime bundled with Ignition unless a project-specific support decision requires otherwise.

  • Custom project scripts, external libraries, or Expert-mode D3 code should be validated against the target browser and Ignition version.

  • Ultra Charts renders in the Perspective browser session, so client browser performance and data size directly affect chart responsiveness.


Last updated: